BMW · Mini · Rolls-Royce — fault codes starting with 247

17 fault codes starting with 247 on BMW · Mini · Rolls-Royce vehicles, with descriptions: 247000, 247036, 247100 and more. Look up a code, read what it means.

Fault codes
17
Block
247
Make group
BMW · Mini · Rolls-Royce
Source language
English · German

The 17 BMW · Mini · Rolls-Royce fault codes that start with 247, with descriptions.

CodeDescriptionGerman
247000Rail pressure plausibility CPC (coupled pressure / volume control): below minimum pressureRaildruck-Plausibilität CPC (gekoppelte Druck/Mengen-Regelung): Minimaldruck unterschritten
247036DMA_FAULTDMA_FAULT
247100Rail pressure plausibility CPC (coupled pressure / volume control): maximum pressure exceededRaildruck-Plausibilität CPC (gekoppelte Druck/Mengen-Regelung): Maximaldruck überschritten
247200247200 xDFC_RailCPCTnkLo1: set value of PCV not in plausibility range247200 xDFC_RailCPCTnkLo1: set value of PCV not in plausibility range
247300247300 xDFC_RailCPCTnkLo3: minimum rail pressure exceeded247300 xDFC_RailCPCTnkLo3: minimum rail pressure exceeded
247400247400 xDFC_RailCPCTnkLo4: maximum rail pressure exceeded247400 xDFC_RailCPCTnkLo4: maximum rail pressure exceeded
247500Rail pressure plausibility volume-controlled: rail pressure too low / positive control deviationRaildruck-Plausibilität mengengeregelt: Raildruck zu niedrig/positive Regelabweichung
247600Rail pressure plausibility volume-controlled: rail pressure too low / positive control deviation and manipulated variable too highRaildruck-Plausibilität mengengeregelt: Raildruck zu niedrig/positive Regelabweichung und Stellgröße zu hoch
247700Rail pressure plausibility volume-controlled: Rail pressure too high with maximum control of the volume control valve (RA negative)Raildruck-Plausibilität mengengeregelt: Raildruck zu hoch bei Maximalansteuerung Mengenregelventil (RA negativ)
247800247800 xDFC_RailMeUn22: maximum negative rail pressure deviation with metering unit on lower limit is exceeded (second stage)247800 xDFC_RailMeUn22: maximum negative rail pressure deviation with metering unit on lower limit is exceeded (second stage)
247900Rail pressure plausibility volume-controlled: below minimum pressureRaildruck-Plausibilität mengengeregelt: Minimaldruck unterschritten
247A00Rail pressure plausibility volume controlled: maximum pressure exceededRaildruck-Plausibilität mengengeregelt: Maximaldruck überschritten
247B00247B00 xDFC_RailMeUn42: maximum rail pressure exceeded (second stage)247B00 xDFC_RailMeUn42: maximum rail pressure exceeded (second stage)
247C00247C00 xDFC_RailMeUn5: positive deviation of rail pressure under fast condition exceeded247C00 xDFC_RailMeUn5: positive deviation of rail pressure under fast condition exceeded
247D00247D00 xDFC_RailMeUnTnkLo0: maximum positive deviation of rail pressure exceeded for tank lo detection247D00 xDFC_RailMeUnTnkLo0: maximum positive deviation of rail pressure exceeded for tank lo detection
247E00247E00 xDFC_RailMeUnTnkLo1: maximum positive deviation of rail pressure exceeded concerning set flow of fuel for tank lo detection247E00 xDFC_RailMeUnTnkLo1: maximum positive deviation of rail pressure exceeded concerning set flow of fuel for tank lo detection
247F00247F00 xDFC_RailMeUnTnkLo2: maximum negative rail pressure deviation with metering unit on lower limit is exceeded247F00 xDFC_RailMeUnTnkLo2: maximum negative rail pressure deviation with metering unit on lower limit is exceeded

Other blocks

Makes that use these codes

Code descriptions are shown in their source language; records without a translation stay raw. Source: CarCoding fault code database.

Get CarCoding

Connect your ELM327 adapter, read fault codes, and browse module settings on supported vehicles.

The app is free to download.