The 17 BMW · Mini · Rolls-Royce fault codes that start with 247, with descriptions.
| Code | Description | German |
|---|---|---|
247000 | Rail pressure plausibility CPC (coupled pressure / volume control): below minimum pressure | Raildruck-Plausibilität CPC (gekoppelte Druck/Mengen-Regelung): Minimaldruck unterschritten |
247036 | DMA_FAULT | DMA_FAULT |
247100 | Rail pressure plausibility CPC (coupled pressure / volume control): maximum pressure exceeded | Raildruck-Plausibilität CPC (gekoppelte Druck/Mengen-Regelung): Maximaldruck überschritten |
247200 | 247200 xDFC_RailCPCTnkLo1: set value of PCV not in plausibility range | 247200 xDFC_RailCPCTnkLo1: set value of PCV not in plausibility range |
247300 | 247300 xDFC_RailCPCTnkLo3: minimum rail pressure exceeded | 247300 xDFC_RailCPCTnkLo3: minimum rail pressure exceeded |
247400 | 247400 xDFC_RailCPCTnkLo4: maximum rail pressure exceeded | 247400 xDFC_RailCPCTnkLo4: maximum rail pressure exceeded |
247500 | Rail pressure plausibility volume-controlled: rail pressure too low / positive control deviation | Raildruck-Plausibilität mengengeregelt: Raildruck zu niedrig/positive Regelabweichung |
247600 | Rail pressure plausibility volume-controlled: rail pressure too low / positive control deviation and manipulated variable too high | Raildruck-Plausibilität mengengeregelt: Raildruck zu niedrig/positive Regelabweichung und Stellgröße zu hoch |
247700 | Rail pressure plausibility volume-controlled: Rail pressure too high with maximum control of the volume control valve (RA negative) | Raildruck-Plausibilität mengengeregelt: Raildruck zu hoch bei Maximalansteuerung Mengenregelventil (RA negativ) |
247800 | 247800 xDFC_RailMeUn22: maximum negative rail pressure deviation with metering unit on lower limit is exceeded (second stage) | 247800 xDFC_RailMeUn22: maximum negative rail pressure deviation with metering unit on lower limit is exceeded (second stage) |
247900 | Rail pressure plausibility volume-controlled: below minimum pressure | Raildruck-Plausibilität mengengeregelt: Minimaldruck unterschritten |
247A00 | Rail pressure plausibility volume controlled: maximum pressure exceeded | Raildruck-Plausibilität mengengeregelt: Maximaldruck überschritten |
247B00 | 247B00 xDFC_RailMeUn42: maximum rail pressure exceeded (second stage) | 247B00 xDFC_RailMeUn42: maximum rail pressure exceeded (second stage) |
247C00 | 247C00 xDFC_RailMeUn5: positive deviation of rail pressure under fast condition exceeded | 247C00 xDFC_RailMeUn5: positive deviation of rail pressure under fast condition exceeded |
247D00 | 247D00 xDFC_RailMeUnTnkLo0: maximum positive deviation of rail pressure exceeded for tank lo detection | 247D00 xDFC_RailMeUnTnkLo0: maximum positive deviation of rail pressure exceeded for tank lo detection |
247E00 | 247E00 xDFC_RailMeUnTnkLo1: maximum positive deviation of rail pressure exceeded concerning set flow of fuel for tank lo detection | 247E00 xDFC_RailMeUnTnkLo1: maximum positive deviation of rail pressure exceeded concerning set flow of fuel for tank lo detection |
247F00 | 247F00 xDFC_RailMeUnTnkLo2: maximum negative rail pressure deviation with metering unit on lower limit is exceeded | 247F00 xDFC_RailMeUnTnkLo2: maximum negative rail pressure deviation with metering unit on lower limit is exceeded |